Changing Partitions
If you want to move the tape from one partition to the logical
beginning of the other partition (LBOP), use the LOCATE command
with the following parameters:
Set CP (Change Partitions) to 1 to indicate you want to change
partitions.
For Block Address, specify the block you want the tape to be
located to.
Set Partition to 0 if you want the tape located in the second
partition or 1 if you want the tape located in the first partition.
Another Way to Change Partitions An optional method for moving
from one partition to the logical beginning of the other partition is
to issue a MODE SELECT command. Specify page format (PF=1)
and send the Device Configuration Page (Page Code=10h).
Specify the following parameters:
Set CAP (Change Active Partition) to 1 to indicate that you
want the tape to be moved to the other partition.
Set Active Partition to 1 if you want to move to the first
partition, or 0 if you want to move to the second partition.
The EXB-8505 does not reposition the tape until it receives a tape
motion command that requires the repositioning, such as READ
(08h), WRITE (0Ah), or SPACE (11h).
3-28
EXB-8205 and EXB-8505
(Standard and XL)
510503