5. Writethefirstdataset(DS1)tothetape.Whilethedatasetis
being written, issue additional READ POSITION commands as
desired to obtain the locations of individual files, blocks, and so
on contained in the data set.
Note: If you are writing data in 8500c format, remember to
re-enable compression by setting the DCE bit to 1.
Save the data returned for each READ POSITION command; it
will be written later to the data set’s directory (DIR 1).
6. Once the first data set (DS 1) has been written, issue another
READ POSITION command to obtain the starting location for
the first data set’s directory (DIR 1).
Save the information returned for the First Block Location field
(bytes 04 through 07) of the READ POSITION data. This
information will be used later to update the master directory at
the beginning of the tape.
LFMLBOT
2. Issue iterative
READ POSITION
commands
DS 1
1. Write the
data set data
12 MBYTE PAD
3. Store the First
Block Location data
DIRECTORY PAD
2. Store the First
Block Location data
LFMLBOT DS 1
1. Issue a READ
POSITION command
12 MBYTE PADDIRECTORY PAD
May 1994 EXB-8205 and EXB-8505
(Standard and XL)
B-7
Appendix B Directory Support
Seitenansicht 375