Exabyte EXB-8205 Betriebsanleitung Seite 329

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 446
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 328
Byte 09, Bit 7 - WBF (WRITE BUFFERs Follow)
The WBF bit specifies whether the new microcode is being sent using
one or more WRITE BUFFER commands, as follows:
0 – This is the only WRITE BUFFER command, or this is the last
WRITE BUFFER command in a sequence.
1–Thisisoneofseveral(butnotthelast)WRITEBUFFERcommands
in a sequence.
For each setting of the WBF bit, the Parameter List Length field (bytes
06 through 08) specifies the number of bytes to be transferred by the
current command.
Byte 09, Bit 6 - VU (Vendor Unique)
There is no vendor unique definition for this bit. This bit must be 0.
26.3 Exceptions and Error Conditions
The following exceptions and error conditions can occur with the
WRITE BUFFER command.
Aborting a WRITE BUFFER Command or Command
Sequence
To terminate a WRITE BUFFER command or an entire sequence of
WRITE BUFFER commands, send an Abort message to the CTS. This
will reset the CTS. Then, reissue the WRITE BUFFER command or the
entire sequence of WRITE BUFFER commands.
Microcode Not Valid
If the data loaded from the SCSI bus is not valid, the CTS returns
Check Condition status with the sense key set to Medium Error (3h).
The CTS will not attempt to load the new code. If this occurs, make
sure you have the correct file and try again or load new microcode
using a microcode update tape or the CTS Monitor program (refer to
the documentation for CTS Monitor).
May 1994 EXB-8205 and EXB-8505
(Standard and XL)
26-5
26 WRITE BUFFER (3Bh)
Seitenansicht 328
1 2 ... 324 325 326 327 328 329 330 331 332 333 334 ... 445 446

Kommentare zu diesen Handbüchern

Keine Kommentare