To return the
parameters in...
Specify this
Page Code...
And this information will be returned...
Non-page format 00h
a
1 to 5 bytes of vendor-unique parameters
Page format
01h
Read-Write Error Recovery Page
02h
Disconnect/Reconnect Page
0Ah
Control Mode Page
0Fh
Data Compression Page
10h
Device Configuration Page
11h
Medium Partition Page
b
20h
Vendor Unique Parameters Page 1
21h
Vendor Unique Parameters Page 2
22h
Data Compression Status Page
3Fh
All available pages
c
a
If you specify 0 for the Page Code field, ensure that the DBD bit is also set to 0. Otherwise, the
CTS returns Check Condition status with the sense key set to Illegal Request (5h).
b
This page is available for the EXB-8505 writing in 8500c format only.
c
When the Page Code is 3Fh, pages 01h through 22h are returned in the order listed in the table.
Byte 04 - Allocation Length
The Allocation Length byte indicates the amount of memory in bytes
that the initiator has allocated for the return of MODE SENSE
parameters from the CTS.
Non-Page Format For non-page format, the Allocation Length byte can
contain values ranging from 00h to 11h. Table 10-5 lists the valid
values for the Allocation Length byte in non-page format.
To return these parameters... Allocate this length...
No parameter list data
00h
Parameter List Header data
04h
Parameter List Header data and 1 to 5 bytes of
vendor-unique parameters
05h, 06h, 07h, 08h, or 09h
Parameter List Header and Block Descriptor
0Ch
Parameter List Header, Block Descriptor, and 1 to 5
bytes of vendor-unique parameters
0Dh, 0Eh, 0Fh, 10h, or 11h
Table 10-4 Values for the Page Code field in the MODE SENSE command
Table 10-5 MODE SENSE Allocation Lengths (non-page format)
May 1994 EXB-8205 and EXB-8505
(Standard and XL)
10-9
10 MODE SELECT (15h) andMODE SENSE (1Ah)