FSC SK ERP Description
A1h 4h 8, 12
Hardware failure—Head sync error during write.
A2h 4h 8, 12 Underrun error during write.
A3h Bh 13 IPORT write buffer parity error.
A4h 4h 8, 12 DPORT write buffer parity error.
A5h 4h 8
Buffer positioning lost during write abort process.
A6h Bh 13 IPORT read buffer parity error.
A7h 4h 8, 12 DPORT read buffer parity error.
A8h 4h 8, 12 PPORT parity error.
ABh 4h 9,8,3,6
Servo timed out.
ACh 4h 9, 8, 3, 6 Servo software error.
ADh 4h 9, 8, 3, 6 Servo hardware failure.
AEh 3h 9, 8, 3, 6 Unable to achieve or maintain tracking.
AFh Dh 11
PEOT or PEOP was encountered during a tape motion
command.
B0h 3h 9, 8, 3, 6 Tape damaged—unable to achieve or maintain tracking.
B3h 3h 9,8,3,6
LBOT or LBOP write failure—read-back-check criteria not met
after retry limit exceeded.
a
B4h 3h 9, 8, 3, 6 LBOT failure—unable to write tape-mark tracks in 8200 format.
B5h 3h 9 Physical Read Manager could not read LBOT or LBOP.
B6h Dh 11
EOT encountered during buffer flush.
C0h 6h 3 Unit Attention—Power-on reset occurred.
C1h 6h 3 Unit Attention—Data cartridge may have been changed.
C2h 6h 3 Unit Attention—MODE SELECT parameters were changed.
C3h 6h 3
Unit Attention—New microcode was loaded.
C4h 6h 3 Unit Attention—Operator requested media removal.
C5h 6h 3
Unit Attention–Incompatible media (such as metal evaporative)
was rejected after the cartridge was inserted. This error also
occurs if you insert a 160m data cartridge into a non-XL CTS.
C6h 2h 7, 3
Not Ready—Cause not known.
C7h 2h 3 Not Ready, but becoming ready.
C8h 2h 2, 3
A tape motion command is required to move the tape from its
current location.
C9h 2h 7 The command requires a tape, but no tape is loaded.
May 1994 EXB-8205 and EXB-8505