EEPROM
option
Definition Possible values Default
value
Option is
set to...
Ignore
illegal
density
changes
Controls the reporting of
errors if you attempt to
change the Density Code
whenthetapeisnot
positioned at LBOT. This
option controls whether an
error is reported if the
Density Code selected
does not agree with the
current tape format. (See
page 10-17 for information
about the Density Code.)
NO – Report an error if an illegal
density change is attempted and the
tape is not at LBOT.
YES – Do not report an error if an
illegal density change is attempted and
the tape is not at LBOT. However, the
write density will not be changed.
NO
Default
density
reporting
code
Controls the reporting of
00h for the Density Code
in MODE SENSE—see
page 10-17.
NORMAL – The CTS should never
report 00h for the Density Code;
instead, it should report the actual tape
format. Setting the Density Code in
MODE SELECT to 00h will select the
default tape format for the CTS.
00h – The CTS should report 00h for
the Density Code instead of the actual
default tape format. Note that this
option does not affect how the Density
Code in MODE SELECT functions.
NORMAL
True areal
density
selection
Controls whether Density
Codes 8Ch and 90h can
be used for the tape format
in MODE SELECT and
MODE SENSE.
See page A-25 for more
information.
EXB-8500 – Density codes 8Ch and
90h are legal for both MODE SELECT
and MODE SENSE.
SCSI-2 – 8500c format is selected by
setting the Density Code to 15h and the
DCE bit to 1. 8200c format is selected
by setting the Density code to 14h and
the DCE bit to 1. MODE SENSE
echoes these settings for each format.
EXB-8500
Legal
non-LBOT
density
Controls which Density
Code is legal when a
MODE SELECT command
is issued and the tape is
not at LBOT.
When the tape is at LBOT,
the Density Code in MODE
SELECT selects the
default write format for the
CTS.Whenthetapeisnot
at LBOT, the tape format
cannot be changed, and
the Density Code must
match either the tape’s
actual format or the default
write density, depending
on this option.
See page A-28 for more
information.
WRITE – When the tape is not at
LBOT, the MODE SELECT Density
Code must match the default write
density, which may or may not reflect
the tape’s actual format.
READ –WhenthetapeisnotatLBOT,
the MODE SELECT Density Code
must match the actual format of the
tape, which may or may not reflect the
default write density. Echoing the
Density Code returned by MODE
SENSE in a subsequent MODE
SELECT command will always work.
WRITE
A-12
EXB-8205 and EXB-8505
(Standard and XL)
510503
Appendix A EEPROM Options