Note: The CTS returns Check Condition status with the sense key
set to Illegal Request (5h) if the Fixed field in the VERIFY
command is 1 (fixed-length logical blocks) and the Block
Length field in the current MODE SELECT data is 0
(variable-length logical block). The ASC and ASCQ bits are
set to 81h and 00h (fixed/variable mismatch).
Bytes 02 through 04 - Verification Length
The Verification Length field defines the amount of data to be verified,
as follows:
When the Fixed bit is set to 0, the Verification Length field
contains the length of the logical block in bytes. The logical block
can be any size from 0 to 240 Kbytes.
When the Fixed bit is set to 1, the Verification Length field
contains the number of logical blocks to be verified. The block
length is the length specified with the MODE SELECT command.
Note: When the value for the Verification Length field is 0, no data
is verified and the current position of the tape is not changed.
Byte 05, Bits 7 and 6 - Vendor Unique
There are no vendor unique definitions for this command.
May 1994 EXB-8205 and EXB-8505
(Standard and XL)
24-3
24 VERIFY (13h)