Byte 00, Bits 7 through 5 - Peripheral Qualifier
This field, in combination with the Peripheral Device Type field (byte
00, bits 4 through 0), identifies the device currently connected to the
logical unit. The value returned for this field is 0, which indicates that
the specified device is currently connected to the selected logical unit.
If the LUN in the CDB or in the Identify message is not 0, the value
returned for these fields is 7Fh, which indicates that the LUN is
invalid.
Byte 00, Bits 4 through 0 - Peripheral Device Type
This field, in combination with the Peripheral Qualifier field (byte 00,
bits 7 through 5), identifies the device currently connected to the
logical unit. The value returned for this field is 01h, which identifies
the CTS as a sequential access device. If the LUN in the CDB or in the
Identify message is not 0, the value returned for these fields is 7Fh,
which indicates that the LUN is invalid.
Byte 01, Bit 7 - RMB
The value returned for this field is 1, which indicates that the media is
removable.
Byte 01, Bits 6 through 0 - Device-Type Modifier
The value returned for this field is 00h, which indicates that there are
no vendor-specific qualification codes.
Byte 02, Bits 7 and 6 - ISO Version
The value returned for this field is 0h, which indicates that the CTS
does not claim compliance with the International Standardization
Organization (ISO) version of SCSI.
Byte 02, Bits 5 through 3 - ECMA Version
The value returned for this field is 0h, which indicates that the CTS
does not claim compliance with the European Computer
Manufacturers Association (ECMA) version of SCSI.
Byte 02, Bits 2 through 0 - ANSI Version
The value returned for this field is 2h, which indicates that the CTS
supports the current version of the ANSI SCSI-2 standard
(X3T9/89-042).
Byte 03, Bit 7 - AENC
The value returned for this field is 0, which indicates that the CTS
does not have asynchronous event notification capability.
May 1994 EXB-8205 and EXB-8505