Exabyte EXB-8205 Betriebsanleitung Seite 397

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 446
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 396
Processing of Extended Message Out
Figure D-5 shows how Extended Message Out messages are
processed. Note that the Attention signal must coincide with the
message byte numbering sequence. The CTS responds to the
initiator’s Synchronous Data Transfer Request with a transfer period
of xx or 32h (200 nanoseconds), whichever is larger (slower), and a
REQ/ACK offset of yy or Bh (11), whichever is smaller.
Parity Error in Extended Message Out
When parity checking is enabled and the CTS detects a parity error in
the Synchronous Data Transfer Request message received from the
initiator, the CTS stays in the Message Out phase until the Attention
signal goes low. Then, it goes to the Message Out phase again to
request that the initiator reissue the entire message sequence.
May 1994 EXB-8205 and EXB-8505
(Standard and XL)
D-11
Appendix D SCSI Bus Message Processing and Error Recovery
Seitenansicht 396
1 2 ... 392 393 394 395 396 397 398 399 400 401 402 ... 445 446