Byte 02, Bit 4 – Enable Threshold Comparison (ETC)
The ETC field indicates whether threshold comparisons for the
counter are enabled or disabled, as follows:
0 – Threshold comparisons for this counter are disabled.
1 – Threshold comparisons are performed on this counter.
If threshold comparisons are enabled, the CTS compares the
cumulative value to the threshold value when the cumulative value is
updated. When the conditions specified by the Threshold Met Criteria
(TMC) bit are met (see below), the CTS returns Check Condition
status with the sense key set to Unit Attention (6h), the ASC and
ASCQ set to 5Bh and 01h, and the Fault Symptom Code set to CAh.
Byte 02, Bits 3 and 2 – Threshold Met Criteria (TMC)
The TMC field specifies the conditions under which the CTS will
generate a Unit Attention (6h) sense key when comparing the current
cumulative value to the threshold value. Threshold comparisons are
made when the cumulative value is updated. Valid values for this
field are as follows:
00b – Return Unit Attention when the cumulative value is updated
01b – Return Unit Attention when the updated cumulative value
equals the threshold value
10b – Return Unit Attention when the updated cumulative value is
not equal to the threshold value
11b – Return Unit Attention when the updated cumulative value is
greater than the threshold value
Byte 02, Bit 1 – Reserved
This bit is reserved.
Byte 02, Bit 0 – List Parameter (LP)
List parameters are not supported by the CTS, so this bit must be 0.
8-10
EXB-8205 and EXB-8505
(Standard and XL)
510503
8 LOG SELECT (4Ch)