Note: Test 101 erases the trace tables. In addition, the unload button
is disabled during this test.
Setup for Test 101
Before starting this test, power the CTS on but do not insert a data
cartridge. Issue a TEST UNIT READY (00h) command. The CTS must
return Check Condition status. Then, issue a REQUEST SENSE
command. The sense key must be set to Not Ready (no data cartridge
present).
CAUTION
When performing this test, be sure to use a data cartridge that
does not contain needed data (“scratch” data cartridge). Data
on the tape will be destroyed during the write portion of this
test.
Test 110 (Power-on Tests with Tape)
During this test, the CTS performs its power-on RAM and servo
diagnostic tests. If these tests complete successfully, the CTS returns
Good status and positions the tape at LBOT. Improper test setup
causes the CTS to return Check Condition status with the sense key
set to Illegal Request.
The CTS disconnects during this test.
Note: Test 110 erases the trace tables. In addition, the unload button
is disabled during this test.
Setup for Test 110
Before starting this test, power the CTS on and insert a write-enabled,
“scratch” data cartridge. Issue a TEST UNIT READY (00h) command.
The CTS must return Good status.
May 1994 EXB-8205 and EXB-8505
(Standard and XL)
21-7
21 SEND DIAGNOSTIC (1Dh)