Exabyte EXB-8205 Betriebsanleitung Seite 224

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 446
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 223
If You Cannot Issue MODE SELECT Commands
If you cannot issue MODE SELECT commands to set the Density
Code, follow these steps to write tapes in different formats:
1. Obtain a tape that has already been written in the desired
format. This tape must include an LBOT pattern plus data or at
least one filemark (or setmark in 8500c format).
2. Load the previously written tape in the CTS.
3. Issue a SPACE or READ command to move the tape away from
LBOT. The CTS automatically sets the Density Code to the
formatitfindsonthetape.
4. Issue a WRITE or WRITE FILEMARKS command to write
information (data, a filemark, or a setmark).
Note: After you complete steps 2, 3, and 4, the Density Code
remains as set in step 3 for as long as that tape is loaded.
5. Rewind the tape to LBOT.
6. Issue a WRITE or WRITE FILEMARKS command to write new
information to the tape and to overwrite the existing
information. The tape will be written in the desired format.
7. To change the format, repeat steps 1 through 6 with a tape
written in the new format. Or, load a blank tape to write in the
CTS’s power-on default format.
10-68
EXB-8205 and EXB-8505
(Standard and XL)
510503
10 MODE SELECT (15h) and MODE SENSE (1Ah)
Seitenansicht 223
1 2 ... 219 220 221 222 223 224 225 226 227 228 229 ... 445 446

Kommentare zu diesen Handbüchern

Keine Kommentare