Table A-9 lists the data formats resulting when you specify various
combinations of Density Code and the DCE bit in MODE SELECT
with the SCSI-2 option.
Density
Code
DCE
bit
Format of data
written to tape...
Equivalent Density Code
(if you choose the
EXB-8500 option)...
...by the
EXB-8505
...by the
EXB-8205
...for the
EXB-8505
...for the
EXB-8205
00h
a
0 8500 8200 15h 14h
1 8500c 8200c 8Ch 90h
14h
0 8200 8200 14h 14h
1 8200c 8200c 90h 90h
15h
0 8500 n/a 15h n/a
1 8500c n/a 8Ch n/a
7Fh
a
0or1
no change in
format
b
no change in
format
7Fh 7Fh
a
The CTS never returns Check Condition status for Density Codes 00h and 7Fh, even when the tape is not at
LBOT.
b
If the tape is written in 8500c format, changing the DCE bit from 0 to 1 or from 1 to 0 will change the logical
tape format, even if the Density Code is 7Fh. For other formats, changing DCE away from LBOT is illegal.
Effect of True Areal Density Selection Options on MODE
SENSE Data
Table A-10 summarizes the data returned by MODE SENSE for the
Density Code and the DCE bit for each True Areal Density Selection
EEPROM option. (The table assumes a tape is loaded and that an
action command has been executed since the last MODE SELECT.)
Table A-9 Data formats resulting from combinations of Density Code and DCE bit (SCSI-2 option)
A-28
EXB-8205 and EXB-8505
(Standard and XL)
510503
Appendix A EEPROM Options