Setting of Fixed bit in current CDB
Fixed=0
(variable-length logical block)
Fixed=1
(fixed-length logical blocks)
LEOT or LEOP
encountered
during current
write operation
The CTS returns Check Condition
status after all data has been written
to tape. The extended sense data is
set as follows:
Error Code=70h
EOM=1
Sense Key=0h (No Sense)
LBOT=0
The CTS returns Check Condition
status after all data in the buffer and
the block currently being transferred
has been written to tape. The
extended sense data is set as follows:
Valid=1
Error Code=70h
EOM=1
Sense Key=0h (No Sense)
Information bytes=requested
transfer length – actual number
of blocks written to tape
LBOT=0
LEOT or LEOP
encountered
during previous
write operation
(buffered mode)
The CTS returns Check Condition
status after all data has been written
to tape. The extended sense data is
set as follows:
Error Code=70h
EOM=1
Sense Key=0h (No Sense)
LBOT=0
The CTS returns Check Condition
status but does not transfer any data.
The extended sense data is set as
follows:
Valid=1
Error Code=71h (error associated
with previous command)
EOM=1
Sense Key=0h (No Sense)
Information bytes=requested
transfer length
ASC=00h
ASCQ=00h
LBOT=0
Table 25-2 Action if LEOT or LEOP is encountered during a WRITE command