Fixed Length Mode (Fixed = 1)
If the Fixed bit is 1 and the actual length of any one block does not
match the requested block length, the CTS transfers the number of
blocks requested until it encounters the block with the incorrect
length. Then, it terminates the READ command and returns Check
Condition status. The REQUEST SENSE data is set as follows:
Valid 1
ILI 1
Sense Key No Sense (0h)
Information
bytes
Indicate the number of blocks not transferred to the
initiator, including the block with the incorrect length.
ASC 00h
ASCQ 00h
FSC 0Ah
When the READ command terminates in fixed mode, the tape is
positioned after the block with the incorrect length (at the start of the
next logical block).
Illegal Requests
The following conditions cause the CTS to return Check Condition
status with the sense key set to Illegal Request (5h):
The requested block length is greater than 240 KBytes.
The Fixed bit is set to 1 and the block length in the MODE
SELECT command is 0.
The Fixed bit is set to 1 and the SILI bit is set to 1.
The tape is in an invalid position for the CTS to perform a read
operation (a READ command was issued after a WRITE or
WRITE FILEMARKS command).
The CTS is not ready or no data cartridge is loaded.
12-10
EXB-8205 and EXB-8505
(Standard and XL)
510503
12 READ (08h)
Seitenansicht 237