Example 2 To transfer the Parameter List Header, the Block
Descriptor, and the Data Compression Page:
1. Specify 1Ch for the Parameter List Length byte (04h for the
Parameter List Header + 08h for the Block Descriptor + 10h
for the Data Compression Page).
2. Set the Block Descriptor Length byte in the Parameter List
Header to 08h.
Example 3 To transfer the Parameter List Header, the Block
Descriptor, and the Vendor Unique Parameters Page 1:
1. Specify 12h for the Parameter List Length byte (04h for the
Parameter List Header + 08h for the Block Descriptor + 06h
for the Vendor Unique Parameters Page 1).
2. Set the Block Descriptor Length byte in the Parameter List
Header to 08h.
Table 10-3 summarizes the values you should designate for the
Parameter List Length byte when you want to transfer the Parameter
List Header, the Block Descriptor, and only one of the parameter
pages. Use this table as a quick reference when you are interested in
changing the parameters for only one of the MODE SELECT pages.
Designate this
amount...
For this page plus the Parameter List Header and Block
Descriptor...
15h Read-Write Error Recovery Page (Page Code=01h)
18h Disconnect-Reconnect Page (Page Code=02h)
14h Control Mode Page (Page Code=0Ah)
1Ch Data Compression Page (Page Code=0Fh)
1Bh Device Configuration Page (Page Code=10h)
14h (short form) or
16h (long form)
Medium Partition Page (Page Code=11h)*
12h Vendor Unique Parameters Page 1 (Page Code=20h)
12h Vendor Unique Parameters Page 2 (Page Code=21h)
*This page is available for the EXB-8505 writing in 8500c format only.
Table 10-3 Values to designate for the MODE SELECT Parameter List Length (page format)
10-6
EXB-8205 and EXB-8505
(Standard and XL)
510503
10 MODE SELECT (15h) and MODE SENSE (1Ah)